OptiTap SC/APC Pre-Terminated Toneable Drop Cable (1F G.652.D, 4.5 × 9.7 mm)

Item No.: Y-FO-FP-064
1F G.652.D toneable figure-8 drop cable with hardened OptiTap-compatible SC/APC connector: 4.5 × 9.7 mm, 24 AWG tone wire, IL ≤0.3 dB, IEC 60794-1-21.
Description Parameters Company Profile Related Product

A factory-terminated single-fiber drop cable assembly with a hardened SC/APC connector, a figure-8 HDPE jacket, and an integral 24 AWG copper toning conductor for buried-plant locating.

Quick Answer

Choose this assembly when a single-fiber drop terminates at a flush-mounted bulkhead adapter on the subscriber wall and field fusion splicing at the drop point is either impractical or too slow. The cable carries one G.652.D fiber inside a gel-filled 3.0 mm loose tube, two longitudinal FRP strength members, and a 0.5 mm copper toning conductor, all in a 4.5 ± 0.2 × 9.7 ± 0.2 mm figure-8 jacket. Rated tensile load is 1000 N short-term / 800 N long-term to IEC 60794-1-21 method E1, and the hardened connector delivers typical insertion loss below 0.2 dB with return loss above 55 dB. Specify it for aerial self-supporting spans, duct routes up to 1.25 in (31.75 mm), or direct-buried runs that must be locatable through a toning set.

Key Features and Benefits

The nine points below map directly to the assembly’s construction and test data. Every figure is quoted from the manufacturer datasheet or the governing standard; no performance claim is made beyond those sources.

Hardened Single-Fiber SC/APC Connector

The ferrule sits in an environmentally sealed housing built for outside-plant deployment, so the interface tolerates dust, standing water, and repeated mating at the pedestal or premises. The connector is a single-mode SC/APC ground to an 8° contact angle.

Interface Compatibility with OptiTap-Style Adapters

The housing mates with external flush-mounted bulkhead adapters of the OptiTap interface family. Where a network is already built around that hardened interface, the assembly drops into existing ports without a new adapter type. 

One Connector Platform for Dielectric and Toneable Constructions

The connector termination is engineered for the SST-type drop cable family in both its all-dielectric and copper-toned variants, which lets one connector platform serve two inventory lines.

Pull-Through Capability in 1.25-Inch Conduit

With the connector installed and the pulling eye in place, the assembly passes a conduit bore of 1.25 in (31.75 mm). That bore sets the practical minimum duct size for pre-terminated drops; smaller ducts require an unterminated cable pulled first.

Integral Pulling Eye Rated 100 lbf

The connector cap doubles as a pulling eye rated for 100 lbf (445 N) maximum tension. This transfers installation load into the cable structure rather than into the ferrule assembly, which is the mechanism that keeps connector loss stable after a long duct pull.

No Fusion Splicing at the Drop Point

Termination is completed in the factory under controlled cleave and polish conditions. The field operation reduces to cleaning, mating, and securing, which removes the splice closure, the fusion splicer, and the splice-loss variable from the drop segment.

G.652.D Fiber with Standard Single-Mode Limits

Attenuation is ≤0.35 dB/km at 1310 nm and ≤0.22 dB/km at 1550 nm, with cable cut-off at or below 1260 nm. The grade supports full-spectrum operation including the 1625 nm maintenance window used for live-fiber troubleshooting.

Copper Toning Conductor for Locate and Bonding

A 0.5 ± 0.02 mm bare copper conductor runs the cable length. It carries the toning signal used by locate crews to find buried plant, and it provides the bonding path required for metallic members entering a premises under NEC Article 770.

Mechanical Margin Above Typical Aerial Drop Loads

Short-term tensile rating is 1000 N and short-term crush resistance is 1000 N/100 mm, both to IEC 60794-1-21. That margin covers ice and wind loading on short spans and the point loads of clamps and facade fasteners.

RoHS Compliance

Materials conform to Directive 2011/65/EU as amended by (EU) 2015/863.

Application Scenarios

Aerial self-supporting drop to a premises. The FRP members and the figure-8 profile support short aerial spans between a pole or closure and the building facade. Where the span exceeds the calculated limit for the FRP diameter, add a separate messenger and lash the cable to it.
Duct drop through 1.25-inch bore. The pre-terminated end passes a 1.25 in conduit with the pulling eye fitted. This is the configuration that removes the need for a splice closure at the building entry.
Direct-buried drop with locate capability. The copper conductor allows the route to be found with a toning set, which is what makes a buried drop serviceable after a landscape change. Local one-call practice, such as the 811 system in the United States, applies to the buried segment regardless of the toning provision.
Premises entry through a flush-mounted bulkhead adapter. The hardened housing mates to an external bulkhead adapter, so the connector stays outside the building envelope and the indoor run begins after the adapter.
Underground or buried closure termination. The assembly terminates at a hardened port in a pedestal or buried closure, feeding a single subscriber from a distribution point.

Ordering and Configuration

The configuration is built from fixed and selectable attributes. No part-number matrix is published for this item, because the attribute combinations quoted by the factory are not yet encoded; configurations are fixed per project on the quotation.
Attribute Available value Status
Fiber count 1 Fixed
Fiber type G.652.D Fixed on this item
Connector A Hardened OptiTap-compatible SC/APC Fixed
Connector B SC/APC Fixed
Sheath material and color HDPE, black Fixed
Delivery length As required Per order
Packing Wooden drum Standard
CPR / EN 50575 class Not declared on datasheet To be confirmed for EU delivery
Request a Quotation,please Contact the OPELINK fiber cable team

FAQ

What is a toneable drop cable, and why does it carry a copper conductor?
A toneable drop cable contains a metallic conductor that carries a locating tone so buried plant can be found from the surface. The conductor serves two purposes and neither is load bearing: - It radiates the tone injected by a locate transmitter, letting crews trace the route without excavation. - It provides a bonding path for the metallic member entering a premises, as required by NEC Article 770. - At 0.5 mm it is a 24 AWG class conductor, sized for signal and bonding current rather than tensile load.
Is the hardened connector a genuine OptiTap or a compatible equivalent?
It is a compatible hardened connector built to mate with the OptiTap interface, not a Corning-manufactured part. Verify three points before approval: - Mechanical fit in the specific bulkhead adapter model used on the network. - Insertion loss and return loss against the network’s acceptance thresholds, here 0.3 dB maximum and 55 dB minimum. - Pull-out strength against the installation method, here 200 N at the hardened connector.
What pulling tension is permitted through a 1.25-inch conduit?
Maximum pulling tension at the pulling eye is 100 lbf, equivalent to 445 N, and the terminated end requires a bore of at least 1.25 in. Keep two figures separate: - The pulling eye rating of 445 N governs installation; it is the load path during a duct pull. - The connector pull-out rating of 200 N is not an installation allowance and must never be used as one. - The cable’s own short-term tensile rating of 1000 N applies to the cable structure, not to the terminated end.
Does the 0.5 mm copper conductor carry the aerial span load?
No. Span load is carried by the two FRP strength members, not by the copper conductor. Treat the copper as a tone and bonding element only: - A 0.5 mm copper conductor has a breaking load near 100 N, far below any serviceable aerial tension. - Datasheets that label this element a messenger wire are mislabelling it; the FRP members are the messenger function. - For span verification, request the FRP diameter and the factory span table rather than inferring capacity from the copper.
What insertion loss and return loss apply at 1310 nm and 1550 nm?
The connector is specified at typical insertion loss below 0.2 dB and maximum below 0.3 dB, with return loss above 55 dB, and these limits apply at both 1310 nm and 1550 nm. When budgeting a link: - Use the 0.3 dB maximum, not the 0.2 dB typical, for loss budget calculations. - Add cable attenuation at the design wavelength: 0.35 dB/km at 1310 nm, 0.22 dB/km at 1550 nm. - Confirm return loss above 55 dB on the APC endfaces, since the 8° polish is what delivers that figure.
Which standards does this assembly declare compliance with?
Declared references are ITU-T G.652 (08/2024) for fiber, IEC 60794-1-21 for tensile and crush, IEC 60794-1-22 for temperature and water penetration, and RoHS under Directive 2011/65/EU as amended. Additional documents to request: - ANSI/ICEA S-87-640:2023 and Telcordia GR-20-CORE Issue 4 certificates if the project is in North America. - Telcordia GR-3120 Issue 2 for the hardened connector interface. - An EN 50575 declaration of performance if the cable is delivered into the EU.
Can it terminate at a flush-mounted bulkhead adapter on the subscriber wall?
Yes. The environmentally sealed hardened housing is designed for external flush-mounted bulkhead adapters, which keeps the connector outside the building envelope. Three installation conditions apply: - Mount the adapter so the cable entry faces downward where local practice requires a drip loop. - Confirm the adapter model matches the hardened interface before ordering the assembly. - Leave the static bend radius of 92 mm clear behind the adapter; a wall box that forces a tighter bend will induce loss.
What bend radius applies during pulling and in service?
Respect 135 mm while the cable is under tension and 92 mm once installed. The two figures come from the 4.5 mm short axis of the figure-8 profile: - During a duct pull, any sheave, guide or bend must exceed 135 mm radius. - In permanent routing, clamps and facade fasteners must hold the cable to at least 92 mm. - Below −10 °C, double the working radius, because HDPE stiffens and the sheath takes damage before the fiber does.
How is the cable supplied, and what delivery lengths are available?
Cable is supplied on wooden drums with length set as required at order entry, so no fixed reel length should be assumed. Planning points: - State the route length plus pulling and dead-end allowance at order entry; cut lengths are not adjustable after manufacture. - Record the drum number against the port served for later fault tracing. - Confirm drum size and weight against site handling equipment before delivery, since length drives drum mass at 35 kg/km.

Related Guides

Toneable flat drop cable, 1–12 fiber — unterminated toning cable for field termination

H-connector SC/APC patch cord — short factory assembly on the same hardened interface

 

Key Performance Specifications

Optical Performance

Fiber values below are the cable-level limits from the datasheet and apply end to end, excluding connector contributions.
Parameter Specified value
Attenuation at 1310 nm ≤0.35 dB/km
Attenuation at 1383 nm ≤0.35 dB/km
Attenuation at 1550 nm ≤0.22 dB/km
Attenuation at 1625 nm ≤0.24 dB/km
Cable cut-off wavelength ≤1260 nm
Zero-dispersion wavelength 1302–1324 nm
Zero-dispersion slope ≤0.091 ps/(nm²·km)
Mode field diameter at 1310 nm 8.8–9.6 µm
Core/clad concentricity error ≤0.6 µm
Cladding diameter 124.8 ± 0.7 µm
Cladding non-circularity ≤1.0%
Primary coating diameter 245 ± 5 µm
Macro-bend loss, 16 mm radius, 1 turn Δ ≤0.05 dB at 1550 nm
Macro-bend loss, 25 mm radius, 100 turns Δ ≤0.05 dB at 1550 nm

Mechanical and Environmental Specifications

Parameter Short-term Long-term Test method
Tensile strength 1000 N 800 N IEC 60794-1-21, method E1
Crush resistance 1000 N/100 mm 500 N/100 mm IEC 60794-1-21, method E3
Minimum bend radius 135 mm (dynamic) 92 mm (static) Manufacturer specification
Operating and storage temperature −40 °C to +70 °C — IEC 60794-1-22, method F1
Water penetration No ingress — IEC 60794-1-22, method F5

Connector Specifications

Connector position Insertion loss, typical Insertion loss, maximum Return loss Tensile strength
Hardened OptiTap-compatible SC/APC <0.2 dB <0.3 dB >55 dB 200 N
SC/APC (field end) <0.2 dB <0.3 dB >55 dB 100 N

 