ADSS Optical Fiber cable, Outdoor All Dielectric Self-Supporting Fiber Optic Cable

Item No.: Y-FO-FC-018
All Dielectric Self-Supporting Fiber Optic Cable ADSS is loose tube stranded. 200um or 250um Bare Fibers, are positioned into a loose tube made of high modulus plastics. The tubes are filled with a water-resistant filling compound.
Description Parameters Company Profile Related product

Product Overview

ADSS (All-Dielectric Self-Supporting) optical fiber cable is a fully non-metallic, self-supporting aerial cable for installation along high-voltage power transmission and distribution lines. The loose-tube stranded design with gel-filled buffer tubes, aramid yarn strength members, and PE or anti-tracking (AT) outer sheath ensures reliable operation in environments with extreme electromagnetic fields and lightning exposure. Opelink ADSS cables support fiber counts from 2 to 144 cores with span lengths up to 1,200 meters.
All Dielectric Self-Supporting Fiber Optic Cable ADSS
Outdoor ADSS All Dielectric Self-Supporting Fiber Optic Cable

Key Features & Benefits

Feature Benefit
All-Dielectric Construction Zero metallic components — complete EMI immunity, no bonding or grounding
Aramid Yarn Strength Member High tensile strength with low weight; supports spans up to 1,200 m
Gel-Filled Loose Tubes Water-resistant compound protects fibers over 25+ year service life
Anti-Tracking (AT) Sheath Option Special PE compound resists surface tracking on lines up to 220 kV
FRP Central Strength Member Crush resistance and dimensional stability across -40°C to +70°C
SZ-Stranded Construction Round, compact profile for uniform stress distribution

Technical Specifications

All values measured per IEC 60794-1-2.
Parameter Value
Fiber Count 2–144 cores (SM G.652.D / G.655)
Outer Diameter (PE/AT) 12.5 – 17.9 mm
Weight (PE/AT) 125–249 kg/km / 136–266 kg/km
Max Working Tension 1.5 – 18.0 kN
Break Strength 10 – 120 kN
Strength Member CSA 4.6 – 58.8 mm²
Elastic Modulus 7.6 – 26.1 kN/mm²
Thermal Expansion -0.8 – 1.8 × 10⁻⁶/K
Max Span (Typical) 100 – 1,200 m
Operating Temperature -40°C to +70°C
Standards IEC 60794-1-2, IEC 60794-3-20, ISO 9001:2015

Applications

  1. Power Transmission Lines — Aerial fiber backbone along 66–500 kV corridors
  2. Distribution Networks — Medium-voltage (11–35 kV) pole-to-pole fiber links
  3. Railway Communications — Trackside fiber along electrified railways
  4. Long-Span Crossings — River/valley crossings up to 1,200 m
  5. Rural Broadband — Fiber over existing power infrastructure, no trenching

Why Choose Opelink?

Industry-proven: 500+ km deployed across SE Asia, Middle East, and South America.
Dual sheath: PE for standard lines; AT for >35 kV — prevents dry-band arcing.
ISO 9001:2015 with full traceability and IEC 60794 testing on every batch.
Competitive lead times: 2–3 weeks standard; custom span engineering in 5 business days.

Frequently Asked Questions

1. Which ADSS sheath suits lines above 35 kV?

The anti-tracking (AT) sheath is specified above 35 kV, where dry-band arcing erodes standard PE.

  1. AT compound resists surface tracking on lines up to 220 kV.

  2. PE sheath remains the standard choice for lower-voltage and distribution lines.

  3. AT sheath supports 25+ year service life under sustained electric field.

  4. Sheath type is fixed at order stage together with span and core count.

2. Which fiber count range is available?

OPELINK ADSS cable covers 2 to 144 cores in single-mode G.652.D or G.655 fiber.

  1. Outer diameter ranges from 12.5 mm to 17.9 mm.

  2. Weight is 125–249 kg/km with PE sheath and 136–266 kg/km with AT sheath.

  3. Higher core counts use larger strength member cross-sections, up to 58.8 mm².

3. Does ADSS cable meet IEC 60794 requirements?

Yes. ADSS cable is tested to IEC 60794-1-2 and its design is specified under IEC 60794-3-20.

  1. All published values are measured per IEC 60794-1-2.

  2. Mechanical and environmental tests follow the same standard series.

  3. Production is managed under ISO 9001:2015 with full traceability.

4. Does every ADSS batch ship with test records?

Yes. IEC 60794 testing is performed on every production batch under ISO 9001:2015.

  1. Test records accompany each shipment for incoming inspection.

  2. Traceability links fiber, sheath compound and strength member to the batch.

  3. 500+ km has been deployed across SE Asia, Middle East and South America.

5. What working tension should ADSS be installed at?

Stringing tension must not exceed the rated maximum working tension, which ranges from 1.5 kN to 18.0 kN.

  1. Allowable working tension per cable is 4–50 kN; break strength is 10–120 kN.

  2. Final tension is set by sag-tension calculation per IEEE 1222 for the actual span.

  3. Ice and wind loading assumptions change the permitted tension.

6. How is water ingress prevented in loose tubes?

Each loose tube is filled with a water-resistant compound that blocks longitudinal water migration.

  1. Gel filling protects the fibers over a 25+ year service life.

  2. The stranded core and sheath add a second barrier against moisture.

  3. Water-blocking performance is verified within the IEC 60794 test programme.

7. What is the maximum span for ADSS cable?

Span reaches 1,200 m under NESC light loading, with a typical working range of 100–1,200 m.

  1. Span is governed by RTS, sag and ice/wind loads rather than core count alone.

  2. OPELINK runs sag-tension calculations per IEEE 1222 for each project.

  3. Longer crossings are engineered case by case against the cable break strength.

8. What temperature range does ADSS operate in?

ADSS cable is rated for continuous operation from -40 °C to +70 °C.

  1. The FRP central strength member holds dimensional stability across the full range.

  2. Thermal expansion is low, from -0.8 to 1.8 × 10⁻⁶/K depending on the design.

  3. Low expansion keeps sag stable through seasonal temperature swings.

9. What lead time applies to standard ADSS orders?

Standard ADSS orders ship in 2–3 weeks; custom span engineering takes 5 business days.

  1. Quotations are prepared from voltage level, span, core count and sheath type.

  2. Ice and wind load data plus RTS allow a sag-tension check before order.

  3. Documents issued with the quotation follow IEC 60794 and ISO 9001:2015 records.


 
Technical Parameters:
Ref. of outer diameter mm Ref. weight
kg/km
Ref. Max workingtension
KN
Max allowable working tension
KN
Break strength
KN
Strength member CSA mm² Modulus of elasticty KN/mm² Heat expansion coefficient×10-6/k
PE AT
12.5 125 136 1.5 4 10 4.6 7.6 1.8
13.0 132 142 2.25 6 15 7.6 8.3 1.5
13.3 137 148 3.0 8 20 10.35 9.45 1.3
13.6 145 156 3.6 10 24 13.8 10.8 1.2
13.8 147 159 4.5 12 30 14.3 11.8 1.0
14.5 164 177 5.4 15 36 18.4 13.6 0.9
14.9 171 185 6.75 18 45 22.0 16.4 0.6
15.1 179 193 7.95 22 53 26.4 18.0 0.3
15.5 190 204 9.0 26 60 32.2 19.1 0.1
15.6 194 208 10.5 28 70 33.0 19.6 0.1
16.3 211 226 12.75 34 85 40.0 20.1 0.1
16.8 226 242 15.45 41 103 48.0 24.0 -0.4
17.2 236 253 16.2 45 108 51.0 25.1 -0.5
17.9 249 266 18 50 120 58.8 26.1 -0.8