1.Typical Properties
The values below are typical values obtained from production batches under the stated test conditions. They are provided for reference and engineering evaluation and are not specification limits.
Table 1. Typical properties of the thermal gel
| Property |
Unit |
Typical Value |
Test Method |
Test Condition |
| Thermal conductivity |
W/m·K |
18 |
ASTM D5470 (LW-9389) |
80 °C, 40 psi |
| Bond line thickness (BLT) |
μm |
≈ 200 |
ASTM D5470 (LW-9389) |
30 °C, 20 psi zeroing; constant pressure |
| Density |
g/cm³ |
3.20 |
GB/T 533-2008 |
Specific gravity before cure; immersion after cure |
| Extrusion rate |
g/min |
20–30 |
Supplier in-house method |
30 cc syringe, 90 psi, 1 min |
| Dielectric strength |
kV/mm |
3.6 |
ASTM D149-20 |
50 Hz AC |
| Compression stress |
psi |
≈ 70 |
Supplier in-house method |
10 mm/min, 1.0 mm → 0.2 mm |
| Residual stress |
psi |
≈ 8.1 |
Supplier in-house method |
3 min after compression to 0.2 mm |
| Adhesive strength |
psi |
≈ 30 |
GB/T 528-2009 |
Cross tensile (pull-off), 10 mm/min; cohesive failure |
| Coefficient of thermal expansion |
μm/m·°C |
79.04 |
GB/T 36800.2-2018 |
TMA, 25–100 °C, 10 °C/min |
| Hardness |
Shore OO |
59–61 |
Supplier in-house method |
Cured specimen, 25 °C |
| Total mass loss (TML) |
% |
0.05 |
ASTM E595 |
125 °C, 24 h |
| Recovered mass loss (RML) |
% |
0.04 |
ASTM E595 |
125 °C, 24 h |
| Collected volatile condensable materials (CVCM) |
% |
0.01 |
ASTM E595 |
125 °C, 24 h |
| Water vapour regained (WVR) |
% |
0.00 |
ASTM E595 |
125 °C, 24 h; pre-conditioned 23 °C / 50 % RH |
Note: All values are typical data from production batches and are not guaranteed specification limits. Values marked with the supplier in-house method are documented in the corresponding test report, available on request. BLT is the minimum thickness reached by an unconstrained sample under constant pressure at 30 °C after zeroing at 20 psi; the maximum measured value was 0.188–0.195 mm over three batches. Density: 3.201 g/cm³ before cure (specific-gravity method), 3.198 g/cm³ after 85 °C cure and 3.196 g/cm³ after 100 °C cure (immersion), equivalent to a volume shrinkage of 0.094 % and 0.156 %; both methods carry a measurement uncertainty and the figures are for reference. Compression stress was measured on a 25.3 × 25.3 mm contact area; the residual stress peak value was 9.39 psi. Adhesive strength was measured on 25.4 × 25.4 × 0.35 mm nickel-plated specimens cured at 100 °C for 1 h or 85 °C for 3 h, and all joints failed cohesively in the gel. CTE was determined over 25–100 °C only at a heating rate of 10 °C/min under 0.05 N. Outgassing data (TML, RML, CVCM) were obtained at 125 °C for 24 h under approximately 10⁻⁶ Torr; WVR was measured after 24 h at 50 % relative humidity.
2.Thermal Resistance versus Bond Line Thickness
Thermal resistance was measured on a steady-state thermal resistance tester (ASTM D5470) with the hot side at 80 °C and a contact pressure of 40 psi. Three samples were tested at each thickness and the table reports the individual readings together with their average.
Table 2. Thermal resistance as a function of bond line thickness
| Bond line thickness (mm) |
R₁ (°C/W) |
R₂ (°C/W) |
R₃ (°C/W) |
Average (°C/W) |
| 0.2 |
0.142 |
0.146 |
0.144 |
0.144 |
| 0.3 |
0.198 |
0.203 |
0.199 |
0.200 |
| 0.5 |
0.309 |
0.314 |
0.310 |
0.311 |
| 0.7 |
0.420 |
0.425 |
0.421 |
0.422 |
| 1.0 |
0.587 |
0.592 |
0.588 |
0.589 |
| 1.5 |
0.864 |
0.870 |
0.866 |
0.867 |
Note: Measured per ASTM D5470 at 80 °C and 40 psi. The thermal conductivity of 18 W/m·K was obtained by linear regression of the 0.5 mm, 1.0 mm and 1.5 mm data points on the thickness–thermal resistance curve; the 0.2 mm, 0.3 mm and 0.7 mm points were not used in the fit. At the 0.3 mm bond line typical of optical module designs, the measured thermal resistance leaves design margin.
3.Reliability
Reliability was assessed by monitoring the change in thermal resistance before and after each stress. In all three test regimes the change remained at or below 3 %, and no delamination, cracking or pumping-out of the gel was observed.
Table 4. Reliability test summary
| Test |
Condition |
Duration |
Acceptance criterion |
Result |
| High-temperature aging |
100 °C |
2000 h |
ΔRₜₕ ≤ 3 % |
Pass |
| Damp heat |
85 °C / 85 % RH |
2000 h |
ΔRₜₕ ≤ 3 % |
Pass |
| Thermal cycling |
−40 °C ↔ 125 °C
(15 min dwell, 15 min ramp, 1 h/cycle) |
2000 cycles |
ΔRₜₕ ≤ 3 % |
Pass |
Note: Thermal resistance was measured per ASTM D5470 at 80 °C and 40 psi before and after each stress. ΔRₜₕ is the relative change of thermal resistance; a change of 3 % or less is considered stable. Longer aging runs (1000 h and 1000 cycles) were also performed on bonded specimens and showed no separation of the bond line.
7.1 Volatile Condensable Materials
Cured samples were held at 100 °C and inspected at 10, 20, 30 and 60 min. No condensable volatiles were observed on the cooled collector at any of these intervals, which is consistent with the low TML (0.05 %) and CVCM (0.01 %) values reported in Table 1.
7.2 Oil Bleed and Migration
The extent of oil migration was measured on grid paper. A freshly dispensed deposit shows an oil mark of about 1.0 mm after 4 h at room temperature; after cure the mark measures 1.0–1.5 mm and stays within that range from day 1 to day 7. The bleed is therefore self-limiting and remains local to the deposit, which is important where the gel is dispensed close to optical surfaces or electrical contacts.